What: /sys/class/scsi_host/hostX/isci_id Date: June 2011 Contact: Dave Jiang <dave.jiang@intel.com> Description: This file contains the enumerated host ID for the Intel SCU controller. The Intel(R) C600 Series Chipset SATA/SAS Storage Control Unit embeds up to two 4-port controllers in a single PCI device. The controllers are enumerated in order which usually means the lowest number scsi_host corresponds with the first controller, but this association is not guaranteed. The 'isci_id' attribute unambiguously identifies the controller index: '0' for the first controller, '1' for the second. What: /sys/class/scsi_host/hostX/acciopath_status Date: November 2013 Contact: Stephen M. Cameron <scameron@beardog.cce.hp.com> Description: This file contains the current status of the "SSD Smart Path" feature of HP Smart Array RAID controllers using the hpsa driver. SSD Smart Path, when enabled permits the driver to send i/o requests directly to physical devices that are part of a logical drive, bypassing the controllers firmware RAID stack for a performance advantage when possible. A value of '1' indicates the feature is enabled, and the controller may use the direct i/o path to physical devices. A value of zero means the feature is disabled and the controller may not use the direct i/o path to physical devices. This setting is controller wide, affecting all configured logical drives on the controller. This file is readable and writable.