// This file was extracted from the TCG Published
// Trusted Platform Module Library
// Part 3: Commands
// Family "2.0"
// Level 00 Revision 01.16
// October 30, 2014
#include "InternalRoutines.h"
#include "Attest_spt_fp.h"
#include "Quote_fp.h"
//
//
// Error Returns Meaning
//
// TPM_RC_KEY signHandle does not reference a signing key;
// TPM_RC_SCHEME the scheme is not compatible with sign key type, or input scheme is
// not compatible with default scheme, or the chosen scheme is not a
// valid sign scheme
//
TPM_RC
TPM2_Quote(
Quote_In *in, // IN: input parameter list
Quote_Out *out // OUT: output parameter list
)
{
TPM_RC result;
TPMI_ALG_HASH hashAlg;
TPMS_ATTEST quoted;
// Command Output
// Filling in attest information
// Common fields
// FillInAttestInfo may return TPM_RC_SCHEME or TPM_RC_KEY
result = FillInAttestInfo(in->signHandle,
&in->inScheme,
&in->qualifyingData,
"ed);
if(result != TPM_RC_SUCCESS)
{
if(result == TPM_RC_KEY)
return TPM_RC_KEY + RC_Quote_signHandle;
else
return RcSafeAddToResult(result, RC_Quote_inScheme);
}
// Quote specific fields
// Attestation type
quoted.type = TPM_ST_ATTEST_QUOTE;
// Get hash algorithm in sign scheme. This hash algorithm is used to
// compute PCR digest. If there is no algorithm, then the PCR cannot
// be digested and this command returns TPM_RC_SCHEME
hashAlg = in->inScheme.details.any.hashAlg;
if(hashAlg == TPM_ALG_NULL)
return TPM_RC_SCHEME + RC_Quote_inScheme;
// Compute PCR digest
PCRComputeCurrentDigest(hashAlg,
&in->PCRselect,
"ed.attested.quote.pcrDigest);
// Copy PCR select. "PCRselect" is modified in PCRComputeCurrentDigest
// function
quoted.attested.quote.pcrSelect = in->PCRselect;
// Sign attestation structure. A NULL signature will be returned if
// signHandle is TPM_RH_NULL. TPM_RC_VALUE, TPM_RC_SCHEME or TPM_RC_ATTRIBUTES
// error may be returned by SignAttestInfo.
// NOTE: TPM_RC_ATTRIBUTES means that the key is not a signing key but that
// was checked above and TPM_RC_KEY was returned. TPM_RC_VALUE means that the
// value to sign is too large but that means that the digest is too big and
// that can't happen.
result = SignAttestInfo(in->signHandle,
&in->inScheme,
"ed,
&in->qualifyingData,
&out->quoted,
&out->signature);
if(result != TPM_RC_SUCCESS)
return result;
// orderly state should be cleared because of the reporting of clock info
// if signing happens
if(in->signHandle != TPM_RH_NULL)
g_clearOrderly = TRUE;
return TPM_RC_SUCCESS;
}