sampling        5000

[SKIN-MID-FLOOR-BC]
algo_type		ss
sampling		2000
sensor			back_therm
device			cluster1
set_point		40000
set_point_clr		39000
device_max_limit	1804800
time_constant		0

[SKIN-MID-LOW-FLOOR-BC]
algo_type		ss
sampling		2000
sensor			back_therm
device			cluster1
set_point		42000
set_point_clr		41000
device_max_limit	1497600
time_constant   0

[SKIN-LOW-FLOOR-BC]
algo_type		ss
sampling		2000
sensor			back_therm
device			cluster1
set_point		47000
set_point_clr		46000
device_max_limit	1190400
time_constant   0

[HOT-SKIN-VIRTUAL]
algo_type		virtual
trip_sensor		back_therm
sensors 		tsens_tz_sensor13 tsens_tz_sensor0
list_cnt		2
weights 		1 -1
set_point		39000
set_point_clr		36000
sampling		1000
math			0

[VIRTUAL-SS-GPU-SKIN]
algo_type		ss
sensor			HOT-SKIN-VIRTUAL
device			gpu
sampling		2000
set_point		7000
set_point_clr		2000
device_max_limit	414000000

[SKIN-MONITOR]
algo_type       	monitor
sampling        	2000
sensor			back_therm
thresholds      	50000				52000				54000
thresholds_clr  	49000				51000				53000
actions 		cluster0+cluster1+gpu+report	cluster0+cluster1+gpu+report		cluster0+cluster1+gpu+report
action_info		1094400+1190400+414000000+1	883200+902400+342000000+1		300000+300000+257000000+1

[MNH-MONITOR]
algo_type       	monitor
sampling        	2000
sensor			back_therm
thresholds      	50000		52000
thresholds_clr  	49000		51000
actions 		mnh		mnh
action_info		3		4

[BATTERY-MONITOR]
algo_type       	monitor
sampling        	2000
sensor			back_therm
thresholds      	52000
thresholds_clr  	50000
actions 		battery
action_info		3

[SKIN-SHUTDOWN]
algo_type		monitor
sampling		1000
sensor			back_therm
thresholds		58000
thresholds_clr		57000
actions 		shutdown
action_info		1

[THROTTLING-NOTIFY]
algo_type               monitor
sampling                2000
sensor                  back_therm
thresholds              40000
thresholds_clr          39000
actions                 report
action_info             1